Template driven analysis
Simple and comprehensive analysis of unknown samples.
In the regular analysis shortcut, necessary analysis parameters and result processing details are predefined.
Simply click the mouse to create a batch for all the samples that need to be analyzed.
Equipped with Automatic Method Choice function, it can select the optimal set of analysis parameters without user intervention
Quick calibration
Multiple analyte curves display, real-time basic curve calculation, used for editing and measuring calibration standard templates.
Use multivariate regression with addition and multiplication correction models to determine the calibration curve.
Familiar user interface
Provide comprehensive result post-processing, including export and Microsoft ™ Excel support.
An integrated Microsoft SQL Server Express relational database that can store settings and analysis data.
The export and import functions allow you to easily transfer calibration standard samples, methods, or levels from one instrument to another.
Complete network and serial transmission capabilities.
A software platform commonly used with WDXRF Thermo Scientific series instruments.
Supports Thermo Scientific SMS system, fully automated sample analysis.
Monitoring and maintenance tools to maximize system runtime.
Measurement uncertainty and consistency probability for unknown sample analysis.
SCT Manager: SCT sample status and historical records can provide an overview of instrument analysis capabilities and each method at any time.
Comprehensive online contextual help.
True online integrated SPC.
Metal grades, comprehensive database of steel and non-ferrous metals, and cross referencing.
Supports Thermo Scientific ™ ARL iSpark ™ And Thermo Scientific ™ ARL 4460 ™ Spark options for direct reading spectrometers.
Can perform complex calculations, such as soluble/insoluble elements or elemental impurities (quantity, size, and chemical composition), without increasing analysis time.
OXSAS software options
The charge correction function can calculate the weight of materials to be added in order to meet the limit requirements for charges exceeding the quality standards in the furnace.
SPC Full: Online statistical process control with complete graphic package extension.
ARLcom: A software package that utilizes network and serial communication to transmit results to computer applications and printers, or to files, using TCP/IP over a local area network.
Remote sample definition: allows you to register samples from external applications located anywhere on the network.
Compatibility:
ARL iSpark direct reading spectrometer
ARL 4460 direct reading spectrometer
Thermo Scientific ™ ARL ™ Fire assay analyzer